Methods 2 & 2F

C-3D-M10

Air emissions testing equipment

Three dimensional flow sensing console with 10" dual inclined manometer

PPS-Dat-2 & PPS-SPH-4

Air emissions testing equipment

Spherical style three dimensional flow sensing probe

C-3D-Mag

Air emissions testing equipment

Three dimensional flow sensing console with magnehelic gauges

C-2040

Air emissions testing equipment

Method 2-4 (and sometimes 5) Console

Method's Pitots

Air emissions testing equipment

Method's Pitots 2

Air emissions testing equipment

Methods 3, 18 & 6

BSS-10

Air emissions testing equipment

10 Liter bag sampling system

Tedlar Bags

Air emissions testing equipment

BV Series Bag Vessels

Intrinsically safe suitable for Method 18 sampling when equipped with Teflon 3-way valve and Teflon sample line

BRI Series

Tedlar air sampling bag with hose barb valve septum fitting

BR Series 

Tedlar air sampling bag with hose barb valve only

CO-QC4-SS Set

Low flow calibration orifice set

Method 6 Train

M6-SC: M6 Midget Sample Caddy

M6-CB: Insulated Midget Glassware Tray

GSM-6B: Single midget ball joint & O-ring glassware set

UA-12: SS Umblical adapter with thermocouple

UC-25U: 25' umblical & power/TC connector box

UNI-VOS-110

Universal volatile organic sampler low flow metering console

Method 5

M5-SC6

Air emissions testing equipment

Modular sample case with heated filter box & 6-impinger cold box

M5-CFB-H/E & M5-HB-H/E

Air emissions testing equipment

Modular heat & electrical assembly: a spare one of these is your spare hotbox


M5-CFB: compact filter box; ideal for vertical or angle sampling or for limited access applications

Probe Nozzels

Air emissions testing equipment

Single nozzles or set of 7 sizes. available in Pyrex, Quartz, Inconel, Stainless steel & Teflon Coated Stainless Steel 

Method 5 Train

Air emissions testing equipment

Method 5 Continued

Pump House

Air emissions testing equipment

Available in enclosed frame or open frame styles; seperates from console for on-site flexibility and easy transport

Parts & Components

  • C-500 series control console & pump
  • 10" dual inclined manometer, 1" incline, & brass shutoff valves
  • 0-30" Hg vacuum gauge
  • Choice of analog or programmable digital solid state temperature controllers
  • Choice of brass or stainless steel valves & quick connects
  • Backlit LCD temperature readout with 7-station selector switch
  • 4-pin amphenol power connector
  • 1/2" quick connect sample inlet
  • Power, pump, timer, null & orsat power switch controls
  • Rotary vane vacuum pump, 1/3HP, 26" Hg maximum vacuum pressure, 2cfm @ 15"Hg

CO-QCB-Set

Air emissions testing equipment

DGM calibration orifice set; stainless steel or brass, with spreadsheet diskette & carrying case

CO-LFA-84

Air emissions testing equipment

Low flow inlet orifice adapter, converts method 5 console for low flow applications

CO-2G

In line orifice adapter (specify flow rate)

Flexible Umbilical Cables

Air emissions testing equipment

Available in 25' to 200' lengths, 1/2" sample line with 1/2" QC, power line with 4 pin amphensol, 5 TC lines, 3 pressure lines with QC's, full length strain relief

Methods 17 & 23

PRI-TO

Air emissions testing equipment

Stainless steel in-stack thimble filter holder, holds 30 x 100 mm glass fiber thimbles and 34 x 00 mm alundum thimbles


PRI-TO-ST: Teflon coated SS thimble holder for mercury testing

GFS-2-10: stainless steel & 47 mm filter holder

PRI-T-P

Air emissions testing equipment

Pyrex in-stack thimble holder; holds 30x100mm glass fiber thimbles; available with 5/8" tube ends or 13/35 taper joint ends

Riserless Method 23 Glassware

Air emissions testing equipment

fits in standard M5 sample case without riser box

Method 23 Extension Set Glassware

Air emissions testing equipment

GP-150: "S" Connector

GP-151: Horizontal Condensor

GP-152: XAD Trap

GP-153: Short knockout impinger

PLUS: 

Extra ball joint clamps

extra teflon O-rings

Methods 26 & 29

UNI-VOS-110

Universal volatile organic sampler, low flow metering console

Method 26 Glassware

Air emissions testing equipment

M6-SC: Sample Caddy

M6-CB: Glassware Tray

UA-12: Umblical adapter & thermocouple

UC-25U: 25' umblical cable & power box

PRA-P3-3/8: 3' heated probe

M2-VFH: valve/filter heater

Complete Method 26 Train

Air emissions testing equipment

Method 29

This method utilizes standard Method 5 equipment with a longer glassware train, Teflon coated O-rings and Teflon or Teflon coated stainless steel fittings, transitions or unions

VOST

Dual Vost Continuous Sampling system

Air emissions testing equipment

Switch of sorbent tubes & leak check one train while sampling the second train


V-S1: Single VOST sampling system

V-S2: DUAL VOST sampling system

V-SC: VOST sample caddy

PRA-P3-V: 3' heated probe assembly

UC-25U: 25' umblical & connector box

M23-RC: coolant pump

GS-V1 & V2

GS-V1: Single VOST glassware set

GS-V2: Dual VOST glassware set

UNI-VOS-110

Air emissions testing equipment

Universal volatile organic sampler low flow metering console

CO-QC4-SS-Set

Air emissions testing equipment

Low flow calibration orifice set: spreadsheet diskette & carrying case

Hexavalent Chromium (Cr+6)

TWS-375

Air emissions testing equipment

PFA teflon impinger & connector set

Testing Train

Air emissions testing equipment

HC-S1: Hexavalent chrome sampling system

PRN-TU-HC: (inset shown) aspirating nozzle union, all teflon

PRN-ST-HC: Aspirating nozzle union, teflon coated SS